Title 5 PLANNING AND DEVELOPMENT
Chapter 5.13 STANDARDS FOR OUTDOOR LIGHTING
5.13.010 Purpose.
5.13.020 Applicability.
5.13.030 Definitions.
5.13.040 Light measurement technique.
5.13.050 General standards for outdoor lighting.
5.13.060 Lighting in parking lots and outdoor areas.
5.13.070 Lighting for vehicular canopies.
5.13.080 Outdoor sports field/outdoor performance area lighting.
5.13.090 Lighting of outdoor display areas. (i.e. automobile dealerships)
5.13.100 Sign lighting.
5.13.110 Lighting of buildings and landscaping.
5.13.120 Permits.
5.13.130 Nonconformities.
5.13.140 Penalties.
5.13.010 Purpose.
The intent and purpose of this ordinance is to regulate outdoor lighting
so that exterior lights minimize sky glow, glare and light pollution. Adherence
to the standards contained in the ordinance should lower energy cost, yet
illuminate surroundings without causing annoyance to the public and users of
property near the light source by reason of glare and light spill over. (Ord.
0-07-03 (part), 2003)
5.13.020 Applicability.
The ordinance shall apply to outdoor lighting that is constructed or
installed after the effective date of the ordinance. The ordinance does not
apply to any exterior lighting in existence on the effective date of the
ordinance, but it is intended to apply when existing outdoor lighting is changed
by adding, or relocating or increasing illumination.
Exterior lighting
installed upon a building or on a lot at a single-family residence or duplex is
not subject to this ordinance. Apartment buildings having three or more
residential units are subject to the within ordinance. (Ord. 0-07-03 (part),
2003)
5.13.030 Definitions.
(1) “Cutoff fixture” - An outdoor light fixture shielded or
constructed in such a manner that no more than two and one half percent of the
total light emitted by the fixture is projected above the horizontal plane of
the fixture.
(2) “Flood lamp” - A form of lighting designed to
direct its output in a specific direction with a reflector formed from the glass
envelope of the lamp itself. Such lamps are so designated by the manufacturers
and are typically used in residential outdoor area
lighting.
(3) “Flood light” - A form of lighting designed to
direct its output in a diffused, less specific direction, with reflecting or
refracting elements located external to the lamp.
(4) “Footcandle
(FC)” - A quantitative unit measuring the amount of light cast onto a
given point, measured as one lumen per square foot.
(5) “Full cutoff
fixture” - An outdoor light fixture shielded or constructed in such a
manner that it emits no light above the horizontal plane of the
fixture.
(6) “Glare” - The effect produced by a light source
within the visual field that is sufficiently brighter than the level to which
the eyes are adapted, to cause annoyance, discomfort, or loss of visual
performance and visibility.
(7) “IESNA” - The Illuminating
Engineering Society of North America, a nonprofit professional organization of
lighting specialists that has established recommended design standards for
various lighting applications.
(8) “Internal Refractive Lens” -
A glass or plastic lens installed between the lamp and the sections of the outer
fixture globe or enclosure. Refractive refers to the redirection (bending) of
the light as it goes through the lens, softening and spreading the light being
distributed from the light source thereby reducing direct
glare.
(9) “Light source” - The element of a lighting fixture
that is the point of origin of the lumens emitted by the fixture.
(10)
“Light trespass” - Effects of light that strays from the intended
purpose and becomes an annoyance, a nuisance, or a determent to visual
performance. As such, light trespass should always be considered negative,
unlike spill light which can have positive or negative attributes. Light
trespass is the encroachment of light causing annoyance, loss of privacy, or
other nuisance.
(11) “Light pollution” - Spill light which,
because of quantitative or directional characteristics, results in annoyance,
distraction, or a reduction in the ability to see essential information, such as
a traffic signal or the night sky.
(12) “Lumen” - The amount of
light which falls upon an area of one square meter, every point of which is one
meter distant from a source of one candela. Therefore, a one-candela source
produces a total of 12.57 lumens.
(13) “Maintained footcandles”
- Illuminance of lighting fixtures adjusted for a maintenance factor accounting
for dirt build-up and lamp output depreciation. The maintenance factor used in
the design process to account for this depreciation cannot be lower than 0.72
for high-pressure sodium and 0.64 for metal halide and mercury vapor.
(14)
“Medium base” - The size of lamp socket designed to accept a medium
or Edison base lamp.
(15) “Outdoor sports field” - An area
designed for active recreation, whether publicly or privately owned, including
but not limited to baseball/softball diamonds, soccer fields, foot-ball fields,
golf courses and ranges, tennis courts, racetracks, and swimming pools.
(16)
“Outdoor performance area” - An area permanently dedicated to the
public presentation of music, dance, theater, media arts, story-telling,
oratory, or other performing arts, whether publicly or privately owned,
including but not limited to amphitheaters and similar open or semi-enclosed
structures.
(17) “Right-of-Way” - An interest in land to the
city which provides for the perpetual right and privilege of the city, its
agents, franchise holders, successors, and assigns to construct, install,
improve, reconstruct, successors, and assigns to construct, install, improve,
reconstruct, remove, replace, inspect, repair, main-tam, and use a public
street, including related and customary uses of street rights-of-way such as
sidewalks, bike paths, landscaping, mass transit facilities, traffic control,
traffic control devices and signage, sanitary sewer, storm water drainage, water
supply, cable television, electric power, gas, and telephone transmission and
related purposes in, upon, over, below, and across the rights-of-way.
(18)
“Semi-cutoff fixture” - An outdoor light fixture shielded or
constructed in such a manner that it emits no more than five percent of its
light above the horizontal plane of the fixture, and no more than twenty percent
of its light ten degrees below the horizontal plane of the fixture.
(19)
“Shielding” - A design feature or a device that is applied to a
luminaire to prevent its luminous output from being visible from selected
locations or horizontal and/or vertical angles.
(20) “Sky glow”
- The brightening of the night sky that results from the reflection of radiation
(visible and non-visible), scattered from the constituents of the atmosphere
(gaseous molecules, aerosols, and particulate matter), in the direction of the
observer. It comprises two separate components:
(a) “natural sky
glow” that part of the sky glow which is attributable to radiation from
celestial sources and luminescent processes in the earth’s upper
atmosphere.
(b) “artificial sky glow” that part of the sky glow
which is attributable to man-made sources of radiation (e.g., outdoor electric
lighting), including radiation that is emitted directly upwards and radiation
that is reflected from the earth’s surface.
(21) “Spill
light” - Light emitted by a lighting installation which falls outside the
boundaries of the property or right-of-way on which the installation is
located.
(22) “Vehicular canopy” - A roofed, open, drive-through
structure designed to provide temporary shelter for vehicles and their occupants
while making use of a business’ services.
(23) “Wall pack”
- A type of light fixture typically surface-mounted on a vertical wall
surface.
(24) “Wide-body refractive globe” - A translucent lamp
enclosure used with some outdoor fixtures to provide a decorative look
(including but not limited to acorn-and carriage light-style fixtures).
“Wide-body” refers to a wider than average size globe (greater than
15.75” in diameter). “Refractive” refers to the redirection
(bending) of the light as it goes through the lens, rendering the light fixture
more effective. Wide-body refractive globes are intended to soften and spread
the light being distributed from the light source thereby reducing direct glare.
(Ord. 0-07-03 (part), 2003)
5.13.040 Light measurement technique.
Light level measurements shall be made at the property line of the
property upon which the light to be measured is being generated. If measurement
on private property is not possible or practical, light level measurements may
be made at the boundary of the public street right of way that adjoins the
property of the complainant or at any other location on the property of the
complainant. Measurements shall be made at finished grade (ground level), with
the light-registering portion of the meter held parallel to the ground pointing
up. The meter shall have cosine and color correction and have an accuracy
tolerance of no greater than plus or minus five percent. Measurements shall be
taken with a light meter that has been calibrated within the year. Light levels
are specified, calculated and measured in footcandles (FC). All FC values below
are maintained footcandles. (Ord. 0-07-03 (part), 2003)
5.13.050 General standards for outdoor lighting.
(a) Unless otherwise specified in Sections 5.13.060 through 5.13.110
below, the maximum light level shall be 0.5 maintained foot-candle at any
property line in a residential district, or on a lot occupied by a dwelling,
congregate care or congregate living structure, and 2.0 maintained footcandles
at any public street right-of-way, unless otherwise approved by the codes
staff
(b) All floodlights shall be installed such that the fixture shall be
aimed down at least forty-five degrees below horizontal, or the front of the
fixture is shielded such that no portion of the light bulb extends below the
bottom edge of an external shield. Flood lights and display lights shall be
positioned such that any such fixture located within fifty feet of a public
street right-of-way is mounted and aimed perpendicular to the right-of-way, with
a side-to-side horizontal aiming tolerance not to exceed fifteen degrees from
perpendicular to the right-of-way.
(c) All flood lamps emitting one thousand
or more lumens shall be aimed at least sixty degrees below horizontal, or
shielded such that the main beam from the light source is not visible from
adjacent properties or the public street right-of-way.
(d) All wall pack
fixtures shall be cutoff type fixtures.
(e) Service connections for all
freestanding fixtures installed after application of this ordinance shall be
installed underground.
(f) Within Thoroughfare and Special High-way Overlay
Districts, all outdoor lighting fixtures shall be at minimum semi-cutoff
fixtures.
(g) Ground mounted luminaries lighting building facades, steeples,
trees, billboards, signs, flags, etc. (vertical surfaces illuminated from the
bottom up) shall not exceed one hundred seventy-five watts. (Ord. 0-07-03
(part), 2003)
5.13.060 Lighting in parking lots and outdoor areas.
(a) Other than floodlights and flood lamps, all outdoor area and parking
lot lighting fixtures generating more than five thousand initial lumens shall be
cutoff fixtures, or comply with subsection (c) below.
(b) The mounting
height of all outdoor lighting, except outdoor sports field lighting and outdoor
performance area lighting, shall not exceed forty-one feet above finished grade,
unless approved by the codes staff as having no adverse effect. Refer to
subsection 5.13.090 (a) below for light levels.
(c)
Exceptions:
(1) Non-cutoff fixtures may be used when the maximum lumen
output generated by each fixture does not exceed five thousand initial lamp
lumens per fixture.
(2) All metal halide, mercury vapor, fluorescent,
induction, white high pressure sodium and color improved high pressure sodium
lamps used in non-cutoff fixtures shall be coated with an internal white
frosting inside the outer lamp envelope.
(3) All metal halide fixtures
equipped with a medium base socket must utilize either an internal refractive
lens or a wide-body refractive globe.
(4) All non-cutoff fixture open-bottom
lights shall be equipped with full cutoff fixture shields that reduce glare and
limit uplight. (Ord. 0-07-03 (part), 2003)
5.13.070 Lighting for vehicular canopies.
Areas under a vehicular canopy shall have a maximum point of horizontal
illuminance of thirty initial footcandles (FC). Areas outside the vehicular
canopy shall be regulated by the standards of subsection 5.13.050 (a) above.
Lighting under vehicular canopies shall be designed so as not to create glare
off-site. Acceptable methods include one or more of the following:
(a)
Recessed fixture incorporating a lens cover that is either recessed or flush
with the bottom surface (ceiling) of the vehicular canopy.
(b) Light fixture
incorporating shields, or shielded by the edge of the vehicular canopy itself,
so that light is restrained to five degrees or more below the horizontal
plane.
(c) Surface mounted fixture incorporating a flat glass that provides
a cutoff fixture or shielded light distribution.
(d) Surface mounted
fixture, typically measuring two feet by two feet, with a lens cover that
contains at least two percent white fill diffusion material.
(e) Indirect
lighting where light is beamed upward and then reflected down from the underside
of the vehicular canopy. Such fixtures shall be shielded such that direct
illumination is focused exclusively on the underside of the vehicular
canopy.
(f) Other method approved by the codes staff. (Ord. 0-07-03 (part),
2003)
5.13.080 Outdoor sports field/outdoor performance area lighting.
(a) The mounting height of outdoor sports field and outdoor performance
area lighting fixtures shall not exceed eighty feet from finished grade unless
the codes administrator states in writing that the height of the lighting
fixtures should have no adverse effect on surrounding property. (Ord. 0-07-03
(part), 2003)
5.13.090 Lighting of outdoor display areas. (i.e. automobile dealerships)
(a) Parking lot outdoor areas shall be illuminated in accordance with the
requirements for Section 5 .13 .060. Outdoor display areas shall have a maximum
point of illuminance of thirty initial footcandles (FC).
(b) All light
fixtures shall meet the IESNA definition of cutoff fixtures. Forward throw
fixtures (type IV light distribution. as defined by the IESNA) are required
within twenty-five feet of any public street right-of-way. Alternatively,
directional fixtures (such as flood light) may be used provided they shall be
aimed and shielded in accordance with subsections 5.13.050 (a) and (b). (Ord.
0-07-03 (part), 2003)
5.13.100 Sign lighting.
Lighting fixtures illuminating signs shall be aimed and shielded so that
direct illumination is focused exclusively on the sign in accordance with
subsection 5.13.050 (g). (Ord. 0-07-03 (part), 2003)
5.13.110 Lighting of buildings and landscaping.
Lighting fixtures shall be selected, located, aimed, and shielded so that
direct illumination is focused exclusively on the building facade, plantings,
and other intended site features and away from adjoining properties and the
public street right-of-way in accordance with subsection 5.13.050 (g). (Ord.
0-07-03 (part), 2003)
5.13.120 Permits.
(a) Installation or change of outdoor lighting as defined above require a
permit to be is-sued by the codes administrator.
(b) The codes administrator
may allow an applicant for a permit involving outdoor lighting to submit an
informal or hand drawn diagram for exterior lighting changes on existing
buildings so long as such diagram describes the illuminating devices, lamp
fixtures, raised foundations and various devices that are in compliance with
this code. (Ord. 0-07-03 (part), 2003)
5.13.130 Nonconformities.
(a) Following application of this regulation, the installation of outdoor
lighting, replacement of outdoor lighting, and changes to existing light fixture
wattage, type of fixture, mounting, or fixture location shall be made in strict
compliance with this code. Any new construction not conforming to these lighting
ordinances shall be subject to delays in obtaining the certificate of occupancy
and/or financial penalties.
(b) Optional methods of conformance to these
regulations may be obtained by capping, shielding or painting existing
luminaires in order to conform to the definition of “semicutoff’, as
listed in Section 5.13.030, “Definitions.” (Ord. 0-07-03 (part),
2003)
5.13.140 Penalties.
Upon the codes administrator becoming aware that exterior lighting is in
violation of this code, the codes administrator shall issue an order directing
the owner or contractor to stop the violation. In the event that the owner or
contractor, their agents, or employee(s) continue in violation, then the codes
administrator shall seek enforcement of the code in the court of common pleas in
the judicial system of the state of South Carolina or in the alternative the
codes administrator may charge the owner or contractor their agent(s) or
employee(s) with a misdemeanor. Upon conviction the court shall impose a fine or
punishment authorized by law for the commission of a misdemeanor. (Ord. 0-07-03
(part), 2003)